RE: IIS Fails back when prevent failback is checked -
10-05-2004
, 02:13 PM
Uttam,
If I down Node1, failover to Node2 works as designed no issues, when
Node1 comes back online, the IIS Services Group failsback to Node1.
There is no loss in functionality, IIS works as needed. It is just that
the Group fails back to the other Node.
I did Move the group to Node2 and it has stayed there, it is just during
failover from 1 to 2 that the anomialy occurs.
Settings were: Threshold 1, Period 2. I may have changed them some time
back (I fell off of testing for almost two months).
Thanks,
Bill
*** Sent via Developersdex http://www.developersdex.com ***
Don't just participate in USENET...get rewarded for it! |