| | Thread Tools | Display Modes |
#1
| |||
| |||
|
#2
| |||
| |||
|
|
Hello to all At this time I have problems in configuring a cluster in windows 2003 64 bits it has server itanium, with an external storage Eva3000 HP. the problem that gives us the problems es fdisk error. Reservation of cluster disk 'Quorum' has been lost. Please check your system and disk configuration Disk 2 will not be used because it is a redundant path for disk 4. 2/13/2004 5:15:09 PM PartMgr Warning None 59 N/A SERVMUNI14 Disk 2 will not be used because it is a redundant path for disk 4. 2/13/2004 5:15:08 PM Disk Warning None 51 N/A SERVMUNI14 An error was detected on device \Device\Harddisk2\DR2 during a paging operation. |
#3
| |||
| |||
|
#4
| |||
| |||
|
|
-----Original Message----- Are these all on the Clustering HCL? -- Andrew J. Kelly SQL Server MVP "Ana Maria" <anonymous (AT) discussions (DOT) microsoft.com> wrote in message news:BDCD3C63-26F6-4D72-826C-47AEA6EFFE33 (AT) microsoft (DOT) com... Hello to all At this time I have problems in configuring a cluster in windows 2003 64 bits it has server itanium, with an external storage Eva3000 HP. the problem that gives us the problems es fdisk error. Reservation of cluster disk 'Quorum' has been lost. Please check your system and disk configuration Disk 2 will not be used because it is a redundant path for disk 4. 2/13/2004 5:15:09 PM PartMgr Warning None 59 N/A SERVMUNI14 Disk 2 will not be used because it is a redundant path for disk 4. 2/13/2004 5:15:08 PM Disk Warning None 51 N/A SERVMUNI14 An error was detected on device \Device\Harddisk2\DR2 during a paging operation. . |
#5
| |||
| |||
|
|
-----Original Message----- Hello, Ana! You wrote on Fri, 13 Feb 2004 16:31:05 -0800: AM> Hello to all At this time I have problems in configuring a AM> cluster in windows 2003 64 bits it has server itanium, with an AM> external storage Eva3000 HP. the problem that gives us the AM> problems es fdisk error. Reservation of cluster disk 'Quorum' has AM> been lost. Please check your system and disk configuration Disk 2 AM> will not be used because it is a redundant path for disk 4. AM> 2/13/2004 5:15:09 PM PartMgr Warning None 59 N/A SERVMUNI14 Disk 2 AM> will not be used because it is a redundant path for disk 4. AM> 2/13/2004 5:15:08 PM Disk Warning None 51 N/A SERVMUNI14 An error AM> was detected on device \Device\Harddisk2\DR2 during a paging AM> operation. I suspect this is a problem either with the HBA or the HBA drivers, just try to sort out the issue with SAN engineer or open- up a case with HP. HTH -- Gianluca Hotz - SQL Server MVP http://italy.mvps.org - http://www.ghotz.com http://www.ugiss.org - http://www.ugidotnet.org . |
#6
| |||
| |||
|
![]() |
| Thread Tools | |
| Display Modes | |
| |