#1
| |||
| |||
|
#2
| |||
| |||
|
|
ids: 11.5 Is anyone set DRAUTO 1 or 2 and had any trouble ? It Seems that DRAUTO was not availabe among some ids old version and back to alive in later version. What happen with DRAUTO? New ids version solved the problem and give it new life? _______________________________________________ Informix-list mailing list Informix-list (AT) iiug (DOT) org http://www.iiug.org/mailman/listinfo/informix-list |
#3
| |||
| |||
|
#4
| |||
| |||
|
|
Art , For me, DRAUTO seem easier than connection manger. If I control not to allow all the clients to enter the secondary server that they don't even know the ip address or existence of secondary. All the jobs still running on the primary server even if we got two primary server owing to network failure. I guess the worst result is rebuild the HDR. Am I right ? _______________________________________________ Informix-list mailing list Informix-list (AT) iiug (DOT) org http://www.iiug.org/mailman/listinfo/informix-list |
![]() |