Old   
Karl Friedrich
 
Posts: n/a

Default Pervasive System Analyzer and Error 10053 - 12-14-2004 , 04:24 AM






Hello,

a customer reported Error 10053 (An established connection was aborted
by the software in your host machine) in PSA (V8.6) while testing
network communication an a newly installed client. Just before the
server engine was installed on the MS 2000 server and is running.

What could cause this error?

Thanks for any idea
Karl
--

Reply With Quote
  #2  
Old   
Karl Friedrich
 
Posts: n/a

Default Re: Pervasive System Analyzer and Error 10053 - 12-23-2004 , 03:02 AM






Problem solved, but not understood ...

The server had a drive D: which was mapped as G:. The server engine
was installed on G: and the workstations had the server drive D:
mapped as H:

I de-installed the whole thing, installed the server engine directly
on D: and all went well.

Karl

On Tue, 14 Dec 2004 11:24:19 +0100, Karl Friedrich
<k.friedrich (AT) fus (DOT) de> wrote:

Quote:
Hello,

a customer reported Error 10053 (An established connection was aborted
by the software in your host machine) in PSA (V8.6) while testing
network communication an a newly installed client. Just before the
server engine was installed on the MS 2000 server and is running.

What could cause this error?

Thanks for any idea
Karl
--


Reply With Quote
Reply




Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off



Powered by vBulletin Version 3.5.3
Copyright ©2000 - 2012, Jelsoft Enterprises Ltd.